Sample Questions

EPA 608 Technician Certification Sample Questions

9 practice questions with complete answer explanations.

Sample Questions

Question 1environmental_impacts

Which of these refrigerants has the highest ozone depletion potential?

A.HFC-134a
B.CFC-12✓ Correct
C.HCFC-22
D.R-410A

Explanation

CFCs such as CFC-12 contain chlorine and no hydrogen, so they are stable enough to reach the stratosphere, where their chlorine destroys ozone. HCFCs contain hydrogen, break down sooner and have a lower ODP. HFCs such as HFC-134a and the blend R-410A contain no chlorine, so their ODP is zero.

Question 2safety

What is the most a refillable refrigerant cylinder should be filled?

A.60% of its capacity
B.70% of its capacity
C.80% of its capacity✓ Correct
D.95% of its capacity

Explanation

Never fill a cylinder beyond 80% of its capacity. The space left over lets the liquid expand when the cylinder warms; an overfilled cylinder can become full of liquid and rupture.

Question 3three_rs

Cleaning refrigerant for reuse by separating out the oil and passing it through filter-driers, usually at the job site, is called:

A.Recycling✓ Correct
B.Recovery
C.Reclaiming
D.Fractionation

Explanation

Recycling cleans refrigerant with oil separation and filter-driers that reduce moisture, acidity and particles, usually on site. Recovery only removes refrigerant and stores it in an external container. Reclaiming reprocesses it to the purity of the AHRI 700 standard, confirmed by chemical analysis.

Question 4recovery_requirements

Which of these is a small appliance under the Section 608 rules?

A.A rooftop unit with 12 pounds of R-410A
B.A car's air conditioner
C.A 3-ton split-system central air conditioner
D.A household refrigerator charged at the factory with 6 ounces of refrigerant✓ Correct

Explanation

A small appliance is a product manufactured, charged and hermetically sealed in a factory with 5 pounds or less of refrigerant, such as a household refrigerator, window air conditioner or dehumidifier. Car air conditioners are covered by a different rule (Section 609), and the other two hold more refrigerant and are charged in the field.

Question 5recovery_requirements

Using recovery equipment made after November 15, 1993, on a small appliance whose compressor works, how much refrigerant must you recover?

A.80% of the charge, or a vacuum of 4 inches of mercury
B.90% of the charge, or a vacuum of 4 inches of mercury✓ Correct
C.100% of the charge
D.Enough to bring the system to 0 psig

Explanation

With equipment made after November 15, 1993, recover 90% of the refrigerant when the compressor works, or 80% when it does not, or pull a 4-inch mercury vacuum. Equipment made before that date must recover 80% or reach the same 4-inch vacuum.

Question 6leak_repair

A commercial refrigeration system holds 50 pounds or more of an ozone-depleting refrigerant. Above what yearly leak rate must its leaks be repaired?

A.10%
B.30%
C.20%✓ Correct
D.35%

Explanation

For appliances with 50 pounds or more of ozone-depleting refrigerant, the leak-rate triggers are 20% for commercial refrigeration, 30% for industrial process refrigeration and 10% for comfort cooling. Leaks above the trigger must be repaired within 30 days.

Question 7leak_detection

What is the most common sign of a refrigerant leak on a high-pressure system?

A.Oil traces at a joint or fitting✓ Correct
B.Condensation on the suction line
C.A clean condenser coil
D.Higher than normal suction pressure

Explanation

Refrigerant carries compressor oil with it, so oil residue around joints, fittings and valves is the most common general sign of a leak. Leaks are then pinpointed with an electronic detector or soap bubbles.

Question 8refrigeration

Why does a low-pressure chiller need a purge unit?

A.To vent refrigerant safely during a leak test
B.To remove excess oil from the evaporator
C.To raise the head pressure at start-up
D.Because parts of it run below atmospheric pressure, so air and moisture leak in and must be removed✓ Correct

Explanation

In a low-pressure chiller the low side operates in a vacuum, so leaks pull air and moisture in rather than letting refrigerant out. The purge unit removes these non-condensables, which would otherwise raise the head pressure and cut efficiency.

Question 9leak_detection

When pressurizing a low-pressure chiller for a leak test, the pressure should not exceed:

A.10 psig✓ Correct
B.15 psig
C.25 psig
D.150 psig

Explanation

Do not exceed 10 psig when pressurizing a low-pressure system for a leak test. The rupture disc on these chillers is commonly set at 15 psig, so higher pressure could burst it and release the charge.

Test-Taking Tips

  • 1.Pass Core first: no certification counts without it, and its rules come up again in every type.
  • 2.Make one page of the numbers: small-appliance recovery levels, the evacuation table, leak-repair rates, the 80% cylinder fill limit and the 10 psig chiller leak-test limit.
  • 3.For each number, learn which equipment and which date it applies to; wrong answers are usually real numbers from a different row.
  • 4.Know the difference between recover, recycle and reclaim word for word.
  • 5.Practise reading a pressure-temperature chart and converting psig to psia (add 14.7).
  • 6.Take each section as a timed 25-question test and aim for 20 or more correct, a margin above the 18 you need.

Ready to practice more?

Take an interactive quiz with these questions.

Start Quiz →
EPA 608 Technician Certification Sample Questions — Practice with Answers | FullPracticeTests