Scoring Guide

EPA 608 Technician Certification Scoring Guide

How scores are calculated, what they mean, and how to reach your goal score.

Scoring Overview

Each section is scored on its own: you pass a section with 70%, which is 18 of 25 questions (40 CFR Part 82, Subpart F, Appendix D). Core is required for every certification. Core + Type I earns Type I, Core + Type II earns Type II, Core + Type III earns Type III, and passing all four sections earns Universal certification. At most certifying organizations a section you pass stays passed, so you retake only the sections you missed. Some organizations also offer Type I as an open-book test. Its pass mark is 84% (21 of 25), and it cannot be combined with the other sections for Universal. Our report shows pass or fail for each section and which certification your result would earn. The big number is your overall percentage across all the questions you took.

Score Scale

SectionDurationMax Score
Core45 min25
Type I — Small appliances45 min25
Type II — High-pressure appliances45 min25
Type III — Low-pressure appliances45 min25

Section Breakdown

core

The rules and science every certified technician needs; required for any certification.

How refrigerants deplete ozone and warm the climateClean Air Act, Montreal Protocol and the venting prohibitionSection 608 rules: recovery equipment, reclaim standard, sales restrictionRecover, recycle and reclaimSubstitute refrigerants, oils and fractionationRefrigeration cycle, gauges and leak detectionDehydration and evacuationSafety: cylinders, the 80% fill limit, nitrogen, PPEShipping and cylinder labels

type1

Small appliances: products made, charged and hermetically sealed in a factory with 5 pounds or less of refrigerant.

Small-appliance definitionRecovery levels by recovery-equipment date (before or after 15 November 1993)Passive (system-dependent) and active recoveryAccess valves and piercing valvesIdentifying refrigerant and non-condensables with pressure and temperatureDecomposition products and safety

type2

High-pressure and very high-pressure appliances such as home air conditioners, heat pumps and commercial refrigeration.

Leak detection and leak-repair ratesRequired evacuation levels before opening equipmentMajor and non-major repairsRecovery techniques: liquid and vaporPressure-temperature relationships, psig and psiaEquipment-room safety (ASHRAE Standard 15)

type3

Low-pressure appliances such as centrifugal chillers, whose low side runs below atmospheric pressure.

Leak testing a chiller and its pressure limitsPurge units and non-condensablesRecovery: liquid first, then vapor; water in the tubesRecharging: vapor before liquidRequired evacuation levelsRefrigerant sensors and equipment-room safety

Key Facts

Questions
4 × 25 (100 total)
Passing score
18 of 25 (70%) each
Certifications
Types I–III, Universal
Valid for
Life (no renewal)
Core section
Required for every certification
Time limit
None set by EPA (set by the testing organization)
Format
Closed book, proctored, 4 options per question
Rules
40 CFR Part 82, Subpart F (EPA)

Study Tips

  • 1.Pass Core first: no certification counts without it, and its rules come up again in every type.
  • 2.Make one page of the numbers: small-appliance recovery levels, the evacuation table, leak-repair rates, the 80% cylinder fill limit and the 10 psig chiller leak-test limit.
  • 3.For each number, learn which equipment and which date it applies to; wrong answers are usually real numbers from a different row.
  • 4.Know the difference between recover, recycle and reclaim word for word.
  • 5.Practise reading a pressure-temperature chart and converting psig to psia (add 14.7).
  • 6.Take each section as a timed 25-question test and aim for 20 or more correct, a margin above the 18 you need.
EPA 608 Technician Certification Scoring Guide — How Scores Work | FullPracticeTests